(1)           (2)               (3)       (4)       (5)                     (6)
 1         E         F          6          B         22              NMS   V
|     Position 1   |        Unit number, used where components   have identical circuits.  |   
|     Position 2   |        Circuit function letter and circuit   designation letter which indicate circuit function and the associated system.  |   
|     Position 3   |        Cable number, allocated to   differentiate.  |   
|     Position 4   |        Cable segment letter, which   identifies the segment of cable between two terminals or connections, and   differentiates between segments of the circuit when the same cable number is   used throughout.  Segments are lettered   in alphabetical sequence, excluding the letter I and O.  A different letter is used for each of the   cable segments having a common terminal or connection.  |   
|     Position  5   |        Cable size.  |   
|     Position 6   |        Suffix data, used to indicate the   type of cable and to identify its connection function.  For example, in the example code NMS V   indicates nyvinmetsheath ungrounded cable in a single-phase system.  |